Visma Instruments & Technologies Private Limited

Chennai, Tamil Nadu

GST No. 33AAECV4260A1ZU

Send Email
0804896873091% Response Rate
Search

Home » Products & Services » Radiography


Radiography

Leading Service Provider of watec - black & white video camera and installation of siemens rf x-ray rad system polydoros lx (pl lx) / fluoro vision from Chennai.

Watec - Black & White Video Camera

REQUEST CALLBACK

Watec - Black & White Video Camera
  • Watec - Black & White Video Camera
  • Watec - Black & White Video Camera
  • Watec - Black & White Video Camera
  • +2 Watec - Black & White Video Camera
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 40,000 / PieceGet Latest Price

Service Details:
Minimum Order Quantity1 Piece
Usage/ApplicationCarm Machine, Medical Application
BrandWatec
Model Name/Numberwatec 902B

CCD FRONT FACE The light receiving face of the CCD camera (Dirt, water or oil deposits on the CCD will cause an unclear picture on the monitor. Attach the lens cap to protect the lens and CCD from contamination and damage.)
 LENS MOUNT Mount for the lens (Thread type)
 FOCUSING ADJUSTMENT SCREWS There are 3 hex. adjustment screws each placed at intervals of 120 for fine focusing of the lens.
 AUTO-IRIS SOCKET This socket is for a video auto-iris lens. For DC iris lenses, see the section below
 TRIPOD MOUNTING SCREW HOLES Mounting holes for stands. The size of these threads are 1/4”, 20 threads, 4.5 ±0.2mm, which is the same as any standard camera tripod (U1/4”).
 VIDEO OUT (BNC) The terminal for composite video signal output
 AE MODE CONTROL The switch for the shutter speed mode control according to the object being monitored.
 POWER IN The terminal designed for the DC-plug of the power adaptor
 FUNCTION SWITCHES Functional switches for setting back light, AGC, gamma control. Power Supply Use a stabilized power adaptor designed for DC+12V ±10%, with a current capacity of more than 250mA.
Use the optional DC plug if the shape or polarity of the DC plug of the power adaptor to be used is not compatible with the camera (See the drawing on the right below). The wiring on the connector must be exact. Be careful not to touch the other terminal while wiring. Protect the wiring portion by using insulation tape after wiring. If the above care and attention is not adhered to, damage to the WAT-902B and power adaptor may occur and may also cause fire. Auto-iris Lens Before connecting the auto-iris lens, please make sure that the pin configuration is correct by checking with the following figure below. If the configuration of your iris connector is different from the following, the plug and pins will need to be rewired.
 This auto-iris terminal is only for video auto-iris lenses. Set-up and Operation
1 Ensure that the power to the WAT-902B and the peripheral equipment is turned off before making any connections.
2 Remove the lens mount cap from the WAT-902B and attach the CSmount lens. Use the optional C-mount adaptor (30CMA-R) when a Cmount lens is used.
3 Connect the iris cable to AUTO-IRIS SOCKET on the WAT-902B when an auto-iris lens is being used.
4 Connect VIDEO OUT on the WAT-902B with the monitor, using a coaxial cable with 75 Ω impedance, such as an RG-59 or an RG-6/U. Select a monitor with the same television system as the WAT-902B: EIA or CCIR. A monitor with more than 600TV lines is recommended.
5 Insert the power plug of the power adaptor into POWER IN on the back panel of the WAT-902B. Confirm that the power adaptor is not connected to the power supply before insertion of the power plug into POWER IN.
6 Turn on the power to the WAT-902B, monitor and all other allied equipment. When a picture cannot be obtained on the monitor, or a problem occurs, check and follow the procedure mentioned in the Problems and Trouble Shooting section.


Additional Information:

  • Delivery Time: 2-3 Weeks
Yes! I am interested

Installation of Siemens RF X-ray Rad System Polydoros LX (PL LX) / Fluoro Vision

REQUEST CALLBACK

Installation of Siemens RF X-ray Rad System Polydoros LX (PL LX) / Fluoro Vision
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 7,50,000 / PieceGet Latest Price

Service Details:
BrandSiemens
Tube TypeRotating Anode
Machine TypePortable
I Deal InNew and Second Hand
AERB ApprovedApplied
Operation ModeAutomatic
Technology TypeDigital
Usage/ApplicationHospital

DR (Digital Radiography X-ray)


Ge | Definium 6000 |

Siemens | Axiom Aristos FX |

Fuji | FDR AcSelerate | FDR D-EVO | FDR Go |

IDC | DR Xplorer 1600 | Xplorer 1590 | 2200 X Series | 1600 Xplorer | X3C 1590 | X4C 1590 |

Cura | Digirad | Dream Retrofit FP | Dream ERA FP | Retrofit |

Portable Detector system | Konica | Fuji | Kodak Carestream | Others

 

The Products we handle...

 

CT scanner | Ge | Philips | Hitachi | Toshiba | Shimadzu | Siemens |

Analog Mammography | Ge | Siemens | planmed |

Digital Mammography |Ge | Siemens | Fuji | Pinkview | Planmed |
Ultrasound scanner | Ge | Toshiba | and all other makes |
Dexa Scanner (BMD) | Ge | Hologic |

 

Radiography / Fluoroscopy X-ray Generator / X-ray Equipment (Line Frequency X-ray Generator (LF) / High Frequency X-ray Generator (HF)| Ge | Siemens | Philips | Toshiba | Shimadzu | Sedecal | IMD | EMD | CPI | Poskom | Allengers | and all other makes |

 

CR and Medical Film Printers | Fuji Film |
MRI scanner | Hitachi (Permanent Magnet) 
C-arm | Ge | Siemens | Allengers | Phlips | and all other makes |

Intra Oral Dental X-ray unit / OPG / Cephalostat | Planmeca |
Cathlab | Shimadzu | Ge |
DICOM software & DICOM Work Stations | Ge | Philips | All Other Makes |

 

The solutions we offer...

·       Field Service ( Trouble Shooting | Preventive Maintenance Service )

·       Remote Technical Support

·       Spare support and Parts Repair (X-ray Tube | PCBs | Detector Electrical, Electronics, Mechanical Assembly)

·       Technical Training

·        Refurbishment

·        Site Planning and Inspection for Installation

·        Installation and Dismantling

·        Quality Assurance Checks

We are a team of highly skilled, passionate engineers - experienced in handling all types of Radiology Imaging Equipment -installed all over the world. 25 years of our core Technical Expertise in handling various makes of X-ray, CT scanners, Analog and Digital Mammography system, Ultrasound and MRI based Imaging modalities makes TECSILA, a unique service organization with highly talented engineering team. We have experienced almost all types of technical challenges, which can happen in an Imaging Equipment, during its life time. We are proud to mention, we could successfully provide viable and innovative technical solutions for all these challenges through our commitment and passion for Technology.

Yes! I am interested

X


Explore More Services

Contact via E-mail
Contact via SMS
Shiju (Director)
Visma Instruments & Technologies Private Limited
No. 53, 1st Floor, 1st Street, Jayalakshmi Nagar
Chennai - 600125, Tamil Nadu, India
Call Us: 
Call Response Rate: 91%
Share Us :



© Visma Instruments & Technologies Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Visma Instruments & Technologies Private Limited