Moulivakkam, Chennai, Tamil Nadu
GST No. 33AAECV4260A1ZU
Approx. Rs 36,336 / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Gas Type | Natural Gas |
Detector Features | Hush Feature, Adjustable Sensitivity, Battery Back-Up |
Display Type | Digital |
Power Source | Battery, Plug-In |
Brand | Altair, Drager, Extech |
18-step bar for displaying gas concentration; additional maximum leakage display
Quick reaction time with built-in pump
Flexible gooseneck sensor for checking hard-to-reach pipes and places
Rechargeable batteries for longer performance
The testo 316-2 ensures speedy and sure gas leak detection. This gas leak detector provides you with a quick and reliable means of detecting methane, propane and hydrogen in the surrounding air. The gas concentration is displayed in the form of an easy-to-read bar and an alarm is triggered when a threshold is crossed.
Product DescriptionWhether it’s for carrying out checks on flanges, fittings or any other places that are typically prone to leaking, the testo 316-2 gas leak detector provides you with a speedy and sure means of detecting higher concentrations of methane, propane and hydrogen in the surrounding air.
The testo 316-2 gas leak detector for pinpoint detection of gas leaks
Even if you already know that a pipe is leaking, you normally still have a long way to go before you can actually locate the leak. The testo 316-2 gas leak detector is just the right tool for carrying out such pinpointing gas leak detection. The detector’s easy-to-read 18-step bar display and maximum leakage reading show the concentration of combustible gas in the surrounding air and lead you quickly and reliably to the source of the leak. The detector also has an audible alarm that warns you when a threshold is crossed and a headphone jack which allows you to connect earphones for more focused and productive working in loud or distracting environments.
Delivery Scope
testo 316-2 gas leak detector, power adaptor,earphones.
Methane (CH₄) | |
---|---|
Measuring range | 10 ppm to 4.0 Vol.% |
Lower response threshold | 10 ppm |
1st alarm limit | 200 ppm |
2nd alarm limit | 10000 ppm |
Propane (C₃H₈) | |
---|---|
Measuring range | 10 ppm to 1.9 Vol.% |
Lower response threshold | 10 ppm |
1st alarm limit | 100 ppm |
2nd alarm limit | 5000 ppm |
Leak detection H₂ | |
---|---|
Measuring range | 10 ppm to 4.0 Vol.% |
Lower response threshold | 10 ppm |
1st alarm limit | 200 ppm |
2nd alarm limit | 10000 ppm |
General technical data | |
---|---|
Operating humidity | 20 to 80 %RH |
Storage temperature | -25 to +60 °C |
Weight | 348 g |
Reaction time | t90 < 2 s |
Dimensions | 190 x 57 x 42 mm (without sensors) |
Operating temperature | -5 to +50 °C |
Warranty | 2 years |
Heat up time | 60 s |
Battery type | NiMH battery |
Battery life | 6 h |
Display type | 0 |
Gas leak detection in gas pipes in the heated environment
Gas leak detection is the elementary testing of gas pipe parts for existing leaks. Leaks are detected by testing a connection point; e.g. at fittings, flanges, screw fittings and gas control valves. The most up-to-date way to detect gas leaks is to use an electronic gas detector (“sniffer”)
Approx. Rs 49,500 / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Brand | Riken Keiki |
Model Name/Number | Gx 2009 Multi gas Detector |
Usage/Application | Gas Detection |
Display Type | Digital |
Gas Type | Combustible Gas |
Detector Features | Battery Back-Up |
Power Source | Battery |
Gas Detected | Combustible gases | Oxygen (O2) | Hydrogen sulfide (H2S) | Carbon monoxide (CO) |
Detection Principle | Catalytic combustion | Galvanic cell | Electro-chemical cell | |
Detection Range {Increments} | 0-100%LEL (1%LEL) | 0-40.0%Vol (0.1%Vol) | 0-100.0ppm (0.5ppm) | 0-500.0ppm (1 ppm) |
Sampling Method | Diffusion | |||
Display | Simultaneous display. Digital LCD with segments, auto backlight at alarm display. |
Approx. Rs 23,863 / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Gas Type | Natural Gas |
Brand | Testo |
Model Name/Number | testo 316-1 - Gas leak detecto |
Sensor Type | LPG |
Usage/Application | Industrial |
Weight | 300 g |
Display Type | Digital |
Power Source | Battery |
Battery Type | 9V block battery |
Battery Life | > 5 h |
Warranty | 2 Year |
Hairline cracks in pipes, old and worn out gaskets: even the tiniest of gas leaks in a natural gas pipe can cause enormous problems. The testo 316-1 natural gas leak detector will help you pinpoint the exact position of a leak when the leak has already been detected using a leak measuring device, for example.
The testo 316-1 gas leak detector - the sure and easy way to detect methane gas
The testo 316-1 is an especially easy-to-use gas leak detector with an adjustable sensitivity dial. The gas leak detector is equipped with both a visual and an audible alarm. A yellow LED lights up when the reading is higher than 200 ppm CH4. The LED changes to red when the reading is higher than 10,000 ppm CH4. This special feature allows you to pinpoint the exact position of the leak. The testo 316-1 is also equipped with a flexible gooseneck sensor for locating gas leaks in especially hard-to-reach or otherwise inaccessible places.
The optional TopSafe protective cover is designed to protect your detector against impact and keeps out dust and dirt.
Technical data | |
---|---|
Measuring range |
0 to 10000 ppm CH |
Lower response threshold |
100 ppm |
1st alarm limit |
200 ppm CH (LED yellow) |
2nd alarm limit |
10000 ppm CH (LED red) |
General technical data
Technical data | |
---|---|
Warranty |
2 years |
Heat up time |
30 s |
Battery type |
9V block battery |
Battery life |
> 5 h |
Display type |
rpm - LED |
Additional Information:
Approx. Rs 1.17 Lakh / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Target Gas | Combustibles in air (CH4,i-C4H10,H2,n-C6H10,C7H8,others) Specify one gas when ordering. |
Detection Principle | Catalytic Combustion |
Detection Range (Increments) | 0-100%LEL (1%LEL) |
Gas Alarm | 1st 10%LEL 2nd 50%LEL |
Types of Alarm | Gas alarm Latching,2 alarms Failure alarm Flow failure,Sensor failure,Battery failure,Circui |
Display of Alarm | LED LED's flash Buzzer Buzzer sounds alternating between a low and high pitch Visual indication |
Alarm Sound | more than 95db (A) at 30cm |
Display | Digital LCD with auto backlight Digital display (7 segments) and digital bargraph (50 segments) |
Sampling Method | Sample draw,Minimum 0.75L/min |
Model | GX-8000 LEL | GX-8000 02 |
---|---|---|
Target Gas | Combustibles in air (CH4, i-C4H10, H2, n-C6H10, C7H8, others) Specify one gas when ordering. | Oxygen in air & inert (02) |
Detection Principle | Catalytic Combustion | Galvanic Cell |
Detection Range (Increments) | 0-100%LEL (1%LEL) | 0-40.0% (0.1%) |
Gas Alarm | 1st : 10%LEL 2nd : 50%LEL | Low alarm : 19.5% High alarm : 23.5% |
Types of Alarm | Gas alarm : Latching, 2 alarms Failure alarm : Flow failure, Sensor failure, Battery failure, Circuit failure, Calibration failure | |
Display of Alarm | LED : LED's flash Buzzer : Buzzer sounds alternating between a low and high pitch Visual indication : Indication value flashes. Alarm message displays and flashes. | |
Alarm Sound | more than 95db (A) at 30cm | |
Display | Digital LCD with auto backlight Digital display (7 segments) and digital bargraph (50 segments) | |
Sampling Method | Sample draw, Minimum 0.75L/min | |
Power Souce | AA Alkaline battery (3pcs) : Standard Lithium-ion battery : Option (3 hours for a full charge | |
Continuous Operation | AA Alkaline battery : more than 6 hours Lithium-ion battery : more than 12 hours | AA Alkaline battery : more than 12 hours Lithium-ion battery : more than 20 hours |
Operating Temp & Humidity | -20∼+50°C, -4∼+122°F below 95%RH (Non-condensing) | |
Dimensions & Weight | Approx. 154(W) x 81(H) x 127(0) mm, Approx. 0.9Kg (Alkaline battery)/1.0Kg(Lithium-ion battery) Approx. 6.1"(W) x 3.1 "(H) x 4.9"(0), Approx. 2.0lb (Alkaline battery) / 2.2lb (Lithium-ion battery) | |
Ingress Proof Rating | Equivalent to IP67 | |
Explosion Proof | Intrinsically safe Exia II CT4 | |
Approvals | IECEx, ATEX, TIIS, MED, HK, CE mark Complying to IEC60079-29-1 | |
Additional Features | Indication to show energizing (pilot indicator and pump driving indicator), Activating confirmation beep and LED's flash (every one minute), Pump stop function, Bump test function, IrDA communication, Data logger, Password protection |
Specfications subject to change without notice
Additional Information:
Approx. Rs 60,731 / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Gas Type | Natural Gas |
Brand | Testo |
Model Name/Number | testo 316-1 - Gas leak detector |
Usage/Application | Gas Detection |
Battery Type | 9V block battery Battery life |
Battery Life | > 5 h |
Warranty | 2 Years |
When house owners notify the network operator or fitter hat they can clearly smell gas in the house, a highly explosive gas concentration may already be present (4–17%). The fitter has to use a gas detector with ATEX protection for the basic checking of sections of gas pipes for leaktightness or to locate the leak. Because you have to be sure in a hazardous situation that the gas measuring technology being used does not cause an explosion through its own potential ignition sources.
The testo 316-EX gas leak detector offers this ATEX protection (ATEX approval 94/9/EC). Use the multi-range gas detector to detect methane, propane and hydrogen gases. The gas concentrations are measured in the ppm range with a semiconductor sensor and are shown on the display with a resolution of 1 ppm. Flexible measuring probes mean you can search for leaks even in inaccessible areas.
Technical data | |
---|---|
Measuring range |
0 ppm to 2 Vol.% CH |
Resolution |
1 ppm / 0.1 Vol.% |
Lower response threshold |
1 ppm |
Technical data | |
---|---|
Measuring range |
0 ppm to 1.0 Vol.% CH |
Resolution |
1 ppm / 0.1 Vol.% |
Lower response threshold |
1 |
Leak detection H
Technical data | |
---|---|
Measuring range |
1 ppm t1 2.0 Vol.% H |
Resolution |
1 ppm / 0.1 Vol.% |
Lower response threshold |
1 ppm |
Additional Information:
Approx. Rs 35,675 / UnitGet Latest Price
Service Details:Minimum Order Quantity | 1 Unit |
Gas Type | Natural Gas |
Color | Black |
Display Type | Digital |
Power Source | Battery |
The testo 316-2 gas leak detector for pinpoint detection of gas leaks
Manufactured in Germany with a 2 years of warranty
Technical data | |
---|---|
Measuring range | 10 ppm to 4.0 Vol.% CH |
Lower response threshold | 10 ppm |
1st alarm limit | 200 ppm CH |
2nd alarm limit | 10000 ppm CH |
Technical data | |
---|---|
Measuring range | 10 ppm to 1.9 Vol.% CH |
Lower response threshold | 10 ppm |
1st alarm limit | 100 ppm CH |
2nd alarm limit | 5000 ppm CH |
Leak detection H
Technical data | |
---|---|
Measuring range | 10 ppm to 4.0 Vol.% H |
Lower response threshold | 10 ppm |
1st alarm limit | 200 ppm H |
2nd alarm limit |
|
Additional Information:
Approx. Rs 23,500 / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Brand | Japanese made with one year warranty |
Model | OX-07 |
Application | Industrial, Laboratory |
Application | personal monitoring |
Approx. Rs 17,900 / PieceGet Latest Price
Service Details:Brand | TRITECH |
Individuals need personal protection in hazardous areas at all times without adding extra bulky equipment, and the 03 Series can provide that kind of protection at an affordable price. The GP-03, OX-03, CO-03, and HS-03 models are personal single gas monitors designed for protection from exposure to combustible hydrocarbons, oxygen deficiency, hydrogen sulfide, or carbon monoxide.
Features:Model | GP-03 | OX-03 | HS-03 | CO-03 |
---|---|---|---|---|
Gas Detected | Combustible Gases | Oxygen | Hydrogen Sulfide | Carbon Monoxide |
Detection Principle | Catalytic Combustion | Galvanic cell | Electro-chemical cell | |
Detection Range | 0 ∼ 100%LEL | 0 ∼ 40.0% | 0 ∼ 100.0ppm | 0 ∼ 500ppm |
Increments | 1%LEL | 0.1% | 0.5ppm | 1ppm |
Preset Alarms | 1st : 10%LEL 2nd : 50%LEL OVER : 100%LEL | 1st : 19.5% 2nd : 18.0% OVER : 40.0% | 1st : 5.0ppm 2nd : 30.0ppm STEL : 5.0ppm TWA : 5.0ppm OVER: 100.0ppm | 1st : 25ppm 2nd : 50ppm STEL : 200ppm TWA : 25ppm OVER: 500ppm |
Types of Alarm | Gas alarms: 2 preset alarms, Over scale alarm, STEL, TWA Trouble alarms: Sensor disconnection, Low battery, Calibration error, Clock error, System error | |||
Alarm Method | Latching | Latching | Latching | Latching |
Display of Alarm | Gas alarms: Flashing LEOs, Buzzer, Flashing gas value, Vibration Trouble alarms: Flashing LEDs, continuous buzzer, display of error message | |||
Operating Temp. & Humidity | -20 ∼ +50°C [-4°F - 122°F] 0 ∼ 90%RH (Non-condensing) | -20 ∼ +50°C [-4°F ∼ 122°F] o - 95%RH (Non-condensing) | -20 ∼ +50°C [-4°F ∼ 122°F] 16 ∼ 85%RH (Non-condensing) | |
Power Source | 2 AAA size Alkaline battery (Optional AAA size Ni-MH battery [Eneloop]) | |||
Continuous Operation | Alkaline battery: Approx.35 h Ni-MH battery : Approx.30 h | Alkaline battery: Approx.3000 h Ni-MH battery : Approx.2000 h | ||
Response Time | 90% response within 30 see | 90% response within 20 sec | 90% response within 30 sec | |
Ingress proof | IP 67 | |||
Explosion Proof | Alkaline dry battery version: Exia II CT4 Ni-MH battery version Exia II CT3 | |||
Approvals | IECEx, ATEX | |||
Dimension & Weight | Approx. 57(W) x 70(H) x 26(0) mm [2.1 (W) x 2.64(H) x 0.94(0) inches] with rubber protection cover, 80g [2.8 ounces] | |||
Function | Manual LCD backlight (Automatically ON when alarming), Peak value, Data logging, Time, CAL alarm, BUMP alarm |
*1 STEL and TWA alarms are available on HS-03 and CO-03 only. *2 No alarm, no light at 25°C
Approx. Rs 70,000 / UnitGet Latest Price
Service Details:Minimum Order Quantity | 1 Unit |
Physical State | Powder |
Usage | Industrial, Laboratory, Personal |
The FP-31 is a highly sensitive portable gas Detector specific for formaldehyde detection. It uses a photoelectric photometry method which utilizes colorimetric tablets for detection. A tablet in placed into the instrument, and then a room air sample is pumped onto the tablet for either a 15 minute or a 30 minute period. If formaldehyde is present, it will cause the chemically impregnated tablet surface to darken or stain. The magnitude of the stain directly correlates to the level of formaldehyde in the air. The stain darkness is read by an optical sensor in the FP-31, and then the instrument calculates the formaldehyde concentration. The FP-31 then has a direct readout of the formaldehyde measurement on an easy to read LCD display. The unit is capable of detecting very low levels of formaldehyde, in order to confirm if an area contains safe breathing levels. There are no known interfering gases.
FEATURES:
Model | FP-31 | |
---|---|---|
Target Gas | Formaldehyde (HCHO) in air | |
Detection Principle | Photoelectric photometry method | |
Detection Range | TAB No. 008 | TAB No.009 |
0- O.4ppm | 0-1.00ppm | |
Digit | 0.005ppm | 0.01ppm |
Detection Time | 1,800 Seconds | 900 Seconds |
Display | Digital display with LCD | |
Sampling method | Built-in Pump sampling Flow rate:0.5L/min | |
Operating Temp & Humidity | -10 -+40 degree C, below 90%Rh%RH | |
Memory Capacity | 99 data (automatically- saved after detection) | |
Self-Diagnosis System | Sensor failure, Pump failure, Battery error, System failure | |
Power Supply | Size AA alkaline battery x 4pcs | |
Continuous Operation | Approx. 12 hours | |
Dimensions | 80{W) x 150{H)x 40{D)mm | |
Weight | Approx. 250g without dry-cell battery | |
Remark | Formaldehyde Detector Specified by the Minister of Health, Labor & Welfare in Japan | |
Function | Automatic saved data, Clock function, Datalogger function |
Additional Information:
Approx. Rs 1.17 Lakh / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Display Type | Digital |
Model | GX-8000 |
Measurement Range | 0-100%LEL (1%LEL) / 0-40.0% (0.1%) (O2) |
Target Gas | Combustibles in air (CH4, i-C4H10, H2, n-C6H10, C7H8, others) Specify one gas when ordering. | Oxygen in air & inert (02) |
Detection Principle | Catalytic Combustion | Galvanic Cell |
Detection Range (Increments) | 0-100%LEL (1%LEL) | 0-40.0% (0.1%) |
Gas Alarm | 1st : 10%LEL 2nd : 50%LEL | Low alarm : 19.5% High alarm : 23.5% |
Types of Alarm | Gas alarm : Latching, 2 alarms Failure alarm : Flow failure, Sensor failure, Battery failure, Circuit failure, Calibration failure | |
Display of Alarm | LED : LED's flash Buzzer : Buzzer sounds alternating between a low and high pitch Visual indication : Indication value flashes. Alarm message displays and flashes. | |
Alarm Sound | more than 95db (A) at 30cm | |
Display | Digital LCD with auto backlight Digital display (7 segments) and digital bargraph (50 segments) | |
Sampling Method | Sample draw, Minimum 0.75L/min | |
Power Souce | AA Alkaline battery (3pcs) : Standard Lithium-ion battery : Option (3 hours for a full charge | |
Continuous Operation | AA Alkaline battery : more than 6 hours Lithium-ion battery : more than 12 hours | AA Alkaline battery : more than 12 hours Lithium-ion battery : more than 20 hours |
Operating Temp & Humidity | -20∼+50°C, -4∼+122°F below 95%RH (Non-condensing) | |
Dimensions & Weight | Approx. 154(W) x 81(H) x 127(0) mm, Approx. 0.9Kg (Alkaline battery)/1.0Kg(Lithium-ion battery) Approx. 6.1"(W) x 3.1 "(H) x 4.9"(0), Approx. 2.0lb (Alkaline battery) / 2.2lb (Lithium-ion battery) | |
Ingress Proof Rating | Equivalent to IP67 | |
Explosion Proof | Intrinsically safe Exia II CT4 | |
Approvals | IECEx, ATEX, TIIS, MED, HK, CE mark Complying to IEC60079-29-1 | |
Additional Features | Indication to show energizing (pilot indicator and pump driving indicator), Activating confirmation beep and LED's flash (every one minute), Pump stop function, Bump test function, IrDA communication, Data logger, Password protection |
Approx. Rs 70,000 / PieceGet Latest Price
Service Details:Measurement Range | In ppm |
Display Type | Digital |
Model | SC-8000 |
Model | SC-8000 |
---|---|
Target Gas Detection Range Alarm Point | Please refer to the table on the next page. (Specify one detectable gas and range when ordering.) |
Detection Principle | Electrochemical |
Types of Alarm | Gas alarm : Latching, 2 alarms Failure alarm : Flow failure, Sensor failure, Battery failure, Circuit failure, Calibration failure, Setting current failure |
Display of Alarm | Lamp : LED's flash (high definition LED Buzzer : (Gas alarm) Alternating sound high and low pitch, (Failure alarm) Continuous sound Display : (Gas alarm) Gas concentration on the display flashes. (Failure alarm) Alarm message on the display flashes. |
Alarm Sound | More than 95dB (A) at 30cm |
Sampling Method | Sample draw, approx. 0.5L/min |
Display | Digital LCD with auto backlight Digital display (7 segments) + digital bargraph (50 segments) |
Power Source | Rechargeable Lithium-ion battery (3 hours for a full charge) : Standard (BUL-8000) AA Alkaline battery (3 pes) : Option (BUD-8000) |
Continuous Operation | Lithium-ion battery: more than 25 hours AA Alkaline battery: more than 18 hours |
Operating Temp & Humidity | Operating temp: -20∼+50°C, Humidity 20∼88%RH (without condensing) |
Dimensions & Weight | Dimension : 154(W)x81 (H)x164(D)mm, Weight: approx 1.1 kg (with BUL-8000) |
Ingress Proof Rating | Equivalent to IP67 |
Explosion Proof | Intrinsically safe : Exia II C T4 |
Approvals | IECEx (No.DEK 11.0019), ATEX (No.DEKRA 11ATEX0047), TIIS (No. TC 20086) CE mark |
Additional Features | Self diagnosis system Zero/Span adjustment (Demand zero/Auto zero selectable) Indication to show energizing (pilot indicator and pump driving indicator) IrDA communication, Data logger (interval, Alarm trend, Station ID control) Peak value/Average value display, Buzzer selector switch (2steps High/Low) Bump test function |
Approx. Rs 60,000 / UnitGet Latest Price
Service Details:Minimum Order Quantity | 1 Unit |
Display Type | Digital |
Model Name/Number | SC-8000 Sinle Gas Detector |
Color | Red & Black |
Measurement Range | 24 Type of gases - Refer to Description (Specify one detectable gas and range when ordering.) |
Warranty | 1 Year |
Detectable Gas and Measuring Range for Model SC-8000
Detectable Gas | Chemical Formula | Measuring Range (ppm) | Increments (ppm) | Preset Alarm (ppm) | |
---|---|---|---|---|---|
1st | 2nd | ||||
Ammonia | NH3 | 0∼75.0 | 0.5 | 25.0 | 50.0 |
Arsine | AsH3 | 0∼0.200 | 0.001 | 0.050 | 0.100 |
Bromine | Br2 | 0∼1.00 | 0.01 | 0.30 | 0.60 |
Carbon Monoxide | CO | 0∼75.0 | 0.5 | 25.0 | 50.0 |
Carbon Monoxide | CO | 0∼75.0 | 0.5 | 25.0 | 50.0 |
Chlorine | Cl2 | 0∼1.50 | 0.01 | 0.50 | 1.00 |
Chlorine Trifluoride | CLF3 | 0∼1.00 | 0.01 | 0.30 | 0.60 |
Diborane | B2Hs | 0∼0.300 | 0.002 | 0.100 | 0.100 |
Flourine | F2 | 0∼3.00 | 0.02 | 1.00 | 2.00 |
Germane | GeH4 | 0∼0.800 | 0.005 | 0.200 | 0.400 |
Hydrogen Bromide | HBr | 0∼6.00 | 0.05 | 2.00 | 4.00 |
Hydrogen Chloride | HCI | 0∼6.00 | 0.05 | 2.00 | 4.00 |
Hydrogen Cyanide | HCN | 0∼15.0 | 0.1 | 4.0 | 10.0 |
Hydrogen Fluoride | HF | 0∼3.00 | 0.02 | 1.00 | 2.00 |
Hydrogen Iodide | HI | 0∼5.00 | 0.05 | 1.50 | 3.00 |
Hydrogen Selenide | H2Se | 0∼0.200 | 0.001 | 0.050 | 0.100 |
Hydrogen Sulfide | H2S | 0∼30.0 | 0.2 | 5.0 | 10.0 |
Nitrogen Dioxide | N02 | 0∼15.0 | 0.1 | 5.0 | 10.0 |
Nitrogen Monoxide | NO | 0∼100 | 1 | 25 | 50 |
Ozone | O3 | 0∼1.00 | 0.01 | 0.30 | 0.60 |
Phosphine | PH3 | 0∼1.00 | 0.01 | 0.30 | 0.60 |
Phosphorus Trifluoride | PF3 | 0∼10.0 | 0.1 | 2.0 | 4.0 |
Silane | SiH4 | 0∼15.0 | 0.1 | 5.0 | 10.0 |
Sulfur Dioxide | S02 | 0∼6.00 | 0.05 | 2.00 | 4.00 |
Additional Information:
Approx. Rs 23,000 / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Model Name/Number | OX-07 / Riken keiki |
Display Type | Digital |
Color | Blue |
Measurement Range | 0.0-40.0%vol. (0.1 %vol.) |
Power Source | Alkaline dry cells (2-AA size), 2pcs |
Alarm Level | No alarm |
Warranty | 1 Year |
Gas Detected | Oxygen in air |
Standard Accessories | Hand strap |
The Model OX-07 personal oxygen indicator and alarm is a pocket-sized, lightweight instrument designed for uninterrupted monitoring of oxygen levels. Carried in a pocket, the OX-07 provides hands-free oxygen level and an alarm whenever oxygen level falls below a preset point. A side-mounted jack accepts a plug that connects to an optional alarm buzzer to alert the wearer even in environments with a high background (ambient) noise level.
An alarm for low battery condition warns the user when power is low. The top-mounted oxygen sensor is easily detached for mounting on an optional extension cable to provide remote sampling in tanks or manholes prior to entering these or other potentially hazardous areas.
Type | Type A | Type B |
Gas Detected | Oxygen in air | |
Detection Principle | Galvanic cell | |
Detection Range (Increments) | 0.0-40.0%vol. (0.1 %vol.) | |
Alarm Set Point | Low alarm 19.5%vol. High alarm 23.5%vol. Over 40.0%vol. | No alarm |
Trouble Alarm | Sensor disconnection, low battery, circuit failure, calibration range error | |
Alarm Types | Gas alarm: flashing light, intermittent buzzer and flashing gas value, pulsing vibration | No alarm |
Trouble alarm : flashing light, intermittent buzzer and Display of error message | ||
Display | Digital display | |
Power Source | Alkaline dry cells (2-AA size), 2pcs | |
Continuous Operation | Maximum 5000 hours (at 25°C, and no alarm, no backlight) | |
Safety Design | Intrinsically safe (ExiaIlCT3) | |
Operating Temp. & Humidity | -20°C ∼+50°C : Humidity below 95%RH (non-condensing) | |
Special Functions | Manual backlight for LCD (automatically lit during alarm) Peak hold (maximum and minimum) | |
Dimensions & Weight | Approx.66(W)x114(H)x33(D)mm Approx. 230g (Instrument only) | |
Standard Accessories | Hand strap | |
Optional Accessories | Extension cable 5m, 10m, 20m, 30m, Carrying case |
Additional Information:
Approx. Rs 96,500 / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Brand | Testo |
Measuring Range | -10 to +60 DegreeC |
Model Name/Number | testo 315-3 - CO and CO2 monitor for ambient measurements |
Ambient CO Measuring range | 0 to 100 ppm |
Cutting-edge technology, easy-to-use, rugged design. These are just a few of the features which make the testo 315-3 stand out head and shoulders above the rest. The CO and CO2 monitor is designed to measure carbon monoxide and carbon dioxide parallel in heating systems and ventilation ducts. The readings are presented on an easy-to-read display. A visual and audible alarm are activated when CO/CO2 thresholds are breached. The thresholds can be adjusted to suit your range of applications.
The intelligently designed monitor has an energy-saving lithium polymer rechargeable battery and powers off automatically when not in use.
And here’s yet another practical feature: the CO and CO2 monitor for ambient measurements can also be used in combination with the testo 330-2flue gas analyzer. The CO/CO2 reading scan be transferred directly to the analyzer via the meter’s infrared interface.
Tune up your CO and CO2 monitor with a range of accessories for even more possibilities
testo 315-3 is already well equipped to meet all the demands you would put on a CO and CO2 monitor. The following accessories are designed to allow you to customize your monitor to suit your own individual requirements:
- TopSafe protective casing: water and dirt repellent; provides testo 315-3 CO and CO2 monitor with protection in wet and dirty conditions
- Testo turbo printer: The testo turbo printer enables you to print out on site and provide with the necessary documentation. The results are transferred to the printer via the CO and CO2 monitor’s infrared interface
- Temperature/humidity module: allows you to carry out quick and reliable temperature and humidity measurements
Technical data | |
---|---|
Measuring range | +5 to +95 %RH |
Accuracy | ±2.5 %RH (5 to +95 %RH) |
Resolution | 0.1 %RH |
Technical data | |
---|---|
Measuring range | 0 to 10000 ppm |
Accuracy | ±300 ppm (0 to 4000 ppm) |
Resolution | 10 ppm |
Technical data | |
---|---|
Measuring range | 0 to 100 ppm |
Accuracy | ±3 ppm (0 to 20 ppm) |
Resolution | 0.5 ppm |
Temperature
Technical data | |
---|---|
Measuring range | -10 to +60 °C |
Accuracy | ±0.5 °C (±1 Digit) |
Resolution | 0.1 °C |
Additional Information:
Approx. Rs 45,750 / PieceGet Latest Price
Service Details:Minimum Order Quantity | 1 Piece |
Application | Laboratory, Industrial |
Model | SC-01 |
Built around RIKEN's Latest smart sensor technology, the SC-01 is RIKEN's most versatile personal single toxic gas monitor. The sensors sre interchangeable and automatically recognized by the instrument. Weighing only 215g, it has many features which set it apart from the competiton. For example, it can monitor one specified gas of Ammonia (NH3), Chlorine (CL2), or Sulfur Dioxide(SO2). The SC-01 also has a unique extender cable where the sensor can be attached to the end of a 3 meter cable for quick response, remote monitoring.
The SC-01's large LCD Display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Standard alarm types include vibration, visual, and audible alarms that can be set to latching or self-resetting. Controlled by a microprocessor, the SC-01 continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors, The batteries are simple to replace, requiring no tools to access the battery compartment.
The SC-01 is equipped with datalogging capability as a standard feature which communicates through an IR port with an optional windows based datalogging software program Calibration intervals and reminders are user adjustable and can be set to either go into alarm or to lock the user out of normal measurement mode once a calibration period has expired.
Features:
Detection Principle | Electrochemical Cell |
Measuring Gas I Range | Ammonia (NH3) in air : 0-75ppm Chlorine (CL2) in air : 0-3.0ppm Sulfur Dioxide (S02) in air : 0-6.0ppm Please specify one gas & range when your ordering |
Alarm Operation | Latching and reset function |
Display | Digital LCD, auto backlight during alarm |
Kinds of Alarms | Gas alarm : 1st, 2nd, STEL, TWA, OVER Trouble alarm : Sensor connection, low battery, circuit error, calibration error |
Alarm Method | Gas alarm : Blinking lamp, intermittent buzzer, indication blinking, vibration Trouble alarm : Blinking lamp, intermittent buzzer (two tones) |
Operating Temperature | -20°C to 50°C |
Operating Humidity | Below 95%RH, non-condensing |
Power Source | AA size Alkaline batteries, 2 pes |
Continuous Operating Time | More than 250 hours (at 25°C, no alarm) |
Explosion Proof | Intrinsically Safe, Exia II BT3 |
Function | LCD manual backlight (automatic light at alarms) STEL, TWA alarm function Clock function Datalogging function, IrDA communication to PC |
Standard Accessories | Alligator Clip Rubber Protector AA size Alkaline batteries (2 each) |
Optional Accessories | Belt Clip Datalogging software for PC Extender cable 3m |
Dimensions | 63(W) X 131(H) X 31(D)mm, without sensor top |
Weight | Approx. 215g, including alligator clip and rubber protector (excluding Alkaline batteries) |